Настенный считыватель смарт-карт  МГц; идентификаторы ISO 14443A, смартфоны на базе ОС Android с функцией NFC, устройства с Apple Pay

Timeout error modbus poll

Timeout error modbus poll. Suddenly all modbus instruments stopped giving data. This time-out just says "if you don't Aug 6, 2016 · Posts: 5225. Since the PLC will act as the Modbus TCP Server. Mark81. 0 to V3. Stop bits: 2. 2 KB. modbus. You know that it is obsolete. 1 it seems as though no errors are triggered and control is possible. Rating: (1188) Preliminary result - It seems as though the problem lies with the MB_CLIENT instruction. wrote on 1 Oct 2018, 22:56. 10. Data bits: 8. Response Timeout :1000. Apr 6, 2012 · Apr 6, 2012. Or you can use the strAlert system variable (14. The selection of stack is performed through KConfig menu option “Enable Modbus stack support …” for appropriate communication mode and related configuration keys. So you have some options to eliminate this possibility. 5 seconds = no work. I'd like to poll all the available server addresses to check which ones are available through my program. 修改Modbus读写功能的配置,把从机设备的ID修改为"2"并点击OK,发现通讯异常即"Timeout Error",重启电批后仍出现"Time out Error"。 如下图: 分析,当从机设备只有一个时Modbus Poll默认分配的ID是"1",不能随意更改,否则就会报上述错误。 Aug 14, 2020 · In Windows, go to Device Manager > Ports and see which COM port the USB/485 converter installed on and use that number for the COM port for the Labview master. 12. Serial interface parameters incorrect (buad rate, parity etc. The RS-485 bus is likely half duplex '2-wire'. g. Wired properly? Jul 19, 2023 · Each device works fine on its own (disable another device). It's really 2-wire with a 3rd signal ground wire, but the argument for later. So please excuse my messy code. Generate a rising edge on REQ, wait for BUSY to be set, then negate REQ, Then wait until DONE or ERROR and not BUSY, then repeat. Dec 7, 2023 · Details of the setup are below: Networking: The server running KEPWare and the Modbus device are connected directly together with a single Ethernet cable. In this case, modbus_set_response_timeout() governs the entire handling of the response, the full confirmation response must be received before expiration of the response timeout. Go the the menu and select manage Palette and search for the node-red-contrib-modbus package. Select Modbus TCP/IP under connection. comparing the send message with the table above in my first post, telegraf send exactly what is listed there for each single byte. 120 with subnet 255. Hope someone knows what's going on as I've spent ages trawling through online sources to find the answer to no avail. Apr 30, 2021 · Hello Duris_I. Any comments how to fix the issue? Hi, I have a problem with an embeddedpi with mbpoll reading modbus registers on ttyAMA0 from a simply modbus slave running on windows. 接好线通电并打开Modbus Poll工具成功连接上工业电批。 如下图: 分析,由上图可看出目前唯一连接从机设备的ID为默认的"1",该从机设备中要读取的寄存器起始地址已给出且读取从起始地址 开始往后的10个寄存器值。 3. The Connection and Chart settings are stored in the Workspace file. 095 [hingStatusInfoChangedEvent] - 'modbus:poller:4df4df10' changed from UNINITIALIZED to OFFLINE 2019-03-02 17:36:50. The PROFINET Master Simulator will be used as PROFINET Master, and Modbus Poll will be used as Modbus TCP Client. baudrate = 9600 举报. When we communicate via Modbus RS485 using the Modbus Poll program, we have two slaves. I personally think a 60 second idle timeout is Ok for most Modbus/TCP clients - few OPC or programmer tools WON'T send a poll every second or 2. SAMUEL MARCO i ARMENGOL. , reading only from one instrument, but no Dec 18, 2023 · Timeout Error是Modbus Poll中常见的问题,通常由通讯超时和数据冲突引起。. With the multiple document interface you can monitor several Modbus slaves and/or data areas at the same time. Modbus-RTU is the “original” serial protocol. Jan 15, 2014 · If you are using channels to poll over Modbus, you'll need to use the OnAlert sequence function to capture any alerts (section 5. :000301020002f8 will read register address 258) and I can also do this in Matlab using the instrument control toolbox to open a serial port connection in the same way. com va escriure: Ok I got your idea, the ::poll() is only to check after sending of master packet to determine if packet was send. #include <string>. Apr 24, 2023 · 1. The specification does not mention a particular value for the timeout, because it is not possible to normalize a timeout value for a wide range of MODBUS slaves. Jun 3, 2022 · Добрый день, ситуация страшная; мой WB-MSW v. registers) (Store add) (Status out) Thanks again. When you open a workspace file, Modbus Poll opens all Modbus Windows and displays them in the layout that you saved. Assuming from your previous screenshot, you're using a NI PXI-8431/4 serial interface for RS-485 communications. We can receive/send signals normally. h file indicates a response timeout exception. Modbus timeout. Electronics: ModBus Timeout ErrorHelpful? Please support me on Patreon: https://www. #include <errno. 22. 按照如下设置(链接单片机后,软件自动选择,也可以手动选择。. You might can test this theory by increasing the value in the "Character Time-out (2-1000ms): " field to something fairly high (50ms) for testing. Modscan configures the serial settings for the PC under Connection (connection > connect > Connection Details > Configuration) The energy meter We would like to show you a description here but the site won’t allow us. As you guessed, it requires a Modbus::query() before. The… Modbus Poll : Setup as follow:-Serial port setup : COM 1 / 9600 / 8 / None / 1 Slave id :2 Function : Read holding Register (4x) Address : 0 Quantity : 4 Scan Rate : 1000 ms Modbus Poll is a Modbus master simulator designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. 偶校验(Even Parity). 5. Aug 8, 2016 · Modbus::poll() handles the reply from the slave. This is normally part of the serial port setup for the device. 准备工具: 1根USB转RS232串口线,1台工业电批,1台Pc,1个Modbus Poll工具。 2. About the signal timeoutChanged the documentation says: This signal is emitted if the response is not received within the required timeout. It provides a 3-pin rs-485 connector and the possibility to commute one of the COM rs-232 ports to a rs-485 one. I usually define my timeouts to 1 second with RTU and 500 ms with TCP. port # this is the serial port name H2. com/roelvandepaarWith thanks & praise to God, and with thanks to Nov 27, 2023 · Strange that both ModScan and Modbus Poll would show timeout errors or insufficient bytes under different scenarios when it's an incorrect CRC all the time. 0. When downgrading the version from V4. You can confirm this by disconnecting or powering off the PLC and see if you still receive the same errors in Modbus Poll. Is there any sort of way to reset to avoid this timeout by restarting the Modbus TCP master for each iteration, so that it would not time out? It happens on 172. #include <iostream>. Jan 18, 2021 · I have experimented different types of timeout (10000 ms, 5000 ms, 10000000 ms) and it would work for several iterations of the state machine, and then after would time out. patreon. Cycle power on the slave device if you have changes any serial setting or slave address for the change to be recognized. Generic TCP/RS-485 converters do a poor job, if any, for Modbus because of Modbus RTU's timing requirements. i try to set ENR (i copy program from example) and know the status word to A0FF, it's mean the communication not established and still can't scan from modbus poll Jan 6, 2010 · Checksum error, Insufficient bytes recieved, Timeout - Modbus Poll: Auma Actuators AC 01. How do you set up a Modbus poll? Modbus Poll should now work as expected: Configure Brainboxes ED device to use the Modbus TCP Protocol: Install and open Modbus Poll: Configure the connection to the Brainboxes remote io device, by clicking: Connection > Connect: Set up the Read/Write definitions, in Modbus Poll click: Setup > Read/Write Aug 14, 2014 · Currently when the user puts in an IP that cannot be connected to, my program hangs for around 2 minutes in an attempt to connect and having my app hang for 2 minutes is not an option. total : 11 bits. FYI the command is currently: ADPRW H1 H3 H0CA K1 D204 M321 Where: ADPRW (Slave ID) (Read command) (Start register) (No. When a byte timeout is set, the response timeout is only used to wait for until the first byte of the response. And the poller: OpenHABmodbus21026×499 27. Jun 4, 2018 · The connection parameters are 115200,8,N,1, it is a virtual com port on /dev/ttyACM0. 04 with a kernel including all the drivers for the on board hardware; the slave Dec 27, 2017 · I am trying to connect Matlab to a detector which uses the MODBUS protocol over a serial port. Incorrect slave adddress in the request. I couldn't find a TS-1200 converter in web search so you need to confirm that it is designed for Modbus. Set up the Read/Write definitions, in Modbus Poll click: Setup > Read/Write Definitions: Always set the Slave ID to 255. modbus_configure(&Serial1, 9600, SERIAL_8N1, 1, 2, HOLDING_REGS_SIZE, holdingRegs);,initial is using &Serial but my arduino is YUN which same with leonard, need to modify the &Serial to &Serial 1 in order to compile; I'm using "SimpleModbusSlaveV9" Modbus Poll uses a multiple windows user interface. 点击 Connection -> Connect 。. You can write any text in the Alias cells. Flow control: none. I always receive this message: ** MODBUS Message TIME-OUT **. Dec 8, 2021 · Modbus Poll, by default (when the PLC Addresses option is not checked), uses 0-based register numbering, so when you enter 261 for the address, this equates to 40262. Make sure that the IP addresses Nov 5, 2021 · Tutoriel sur l'usage de Modbus Poll en TCP-IP Apr 27, 2016 · At 4 seconds, I get intermittent errors and the re-connect case works fine. 3 seconds or less = works fine. However, it is a good assumption that you should receive a reply within a few hundreds of milliseconds. Parity: none. You can find it here: https://forums. But you can change this. EDIT 3: I am able to read a register using Modbus Poll. 108 455 subscribers in the MODBUS community. driver polarity is backwards. El dia 10/08/2016 22:53, "Krosik" notifications@github. First look at this pictures and voltage levels seems correct and there is no extra byte at the end of the Rx packet. May 28, 2024 · #1. lowlevel: (RTU client) Sent Serial ADU: 0x0203000000018439. jschulze. It make a new calculation an prints the 2 values as below: Feb 20 06:25:11 RevPi1321 piModbusMaster [539]: modbus rtu action timeout: 0 s 500000 us. When the piControl driver is reset, the modbus master is also reset. However, once we open the communication window, one of the slave encounters a timeout error. 1. also there is RCV_TIMEOUT static parameter which set needed time for check not responding Slave. Any suggestion, inputs are greatly appreciable. We would like to show you a description here but the site won’t allow us. This delay is not implemented in ModbusMaster. 2. This really seems to point to a firmware bug. It will be nice if we Nov 2, 2021 · When getting these errors check the following: • Check to see that Pre-Delay is at least 50 mS. With Qt 5. 1 Check the network configuration. 19200波特率. I'm not an expert at Modbus for sure. h>. But if both devices are enabled, Modbus "readMemory error" will occur frequently which result in not very stable communication . I’m trying to use an Advantech Adam-6060 with modbus but hassio almost always lists the entity as unavailable. Sep 12, 2019 · There should be at least 3. You know that it is primitive. Khi bạn kết nối chưa đúng thì Modbus poll sẽ thông báo No connection ở trên hoặc nổi bảng thông báo Modbus Connection Failed. 1停止bit. The log shows “Pymodbus: Modbus Error: [Input/Output] [Errno 104] Connection reset by peer”. Modbus Poll Modbus Poll คือโปรแกรม ส ำหรับจ ำลองกำรอ่ำนค่ำอุปกรณ์ ด้วย Modbus Protocol โดยมีกำรใช้งำน เบื้อต้นดังนี้ 1. Modbus RTU specification and calculations : 1 start bit + 8 data bits + 1 parity bit + 1 stop bit or 1 start bit + 8 data bits + (no parity bit) + 2 stop bits. Dec 29, 2016 · If you have Gateway, you must think to 2 possibilities in my opinion - you can have problem on TCP connection with Gateway (Server). Fundamentally, modbus is a request response protocol (like your web browser) but with a shared resource (the serial port). There is another format which packages the serial form and sends it over TCP, “Modbus RTU over TCP”, which the OH binding does not support. I can connect via a terminal program and read and write commands manually (e. If logs where generated please post these here using code fences: I get the following in the log: 2019-03-02 17:36:50. Register is 40046, so I understand this to be register 45 of the holding registers? How do I translate this to minimalmodbus? EDIT 4: I am not married to minimal modbus - I am happy to use any tool to get this done Jan 6, 2020 · Platinum Expert. 3 подключён к компьютеру через адаптер CH341A rs-485–>usb, всё работало, затем час постояло во включённом режиме и перестало работать чтение регистров, в modbus poll вываливает две ошибки Aug 9, 2003 · 3) Create an independent "idle timeout" for your server. Dec 17, 2019 · import time import os import serial import minimalmodbus delay = 1 pdata = 1 #-- H2 sensor read out ----- #def getH2(): res = 0 ADRH1 = 1 # read out register for H2 ADRH2 = 0 # read out register for H2 try: H2 = minimalmodbus. #1. serial. 3. Wednesday at 9:09 AM. But you also know that it is everywhere. Export to csv. Update: I tested the very same config with an old Temco unit (T3-8I13O) and I have the same problem through serial: The regular modbus poll program works but the Temco modbus program won’t. Before testing FUXA, both RTU devices worked well with other Scada software. 255. 168. I'm working on a project involving ModBus RTU on rs-485 on the vdx-6354 single board by ICOP. Regards. to” option with the Communications Command called SendCommunicationHandleCommand. Nov 7, 2017 · Example of received and transmitted messages during successful Modbus Serial communication while using Modbus Poll application Dec 19, 2023 · In this example, we use the ABC4017 PROFINET IO Device / Modbus TCP server. Nov 24, 2022 · You say "USB adapter/Raspberry Pi/Modbus RTU: works": can you get the raw bytes and add them to the question? Ideally the same read-holding-registers(6, 1); ideally with the same reply(0x10, 0x1c). Hello, esteemed seniors. Feb 20 06:25:11 RevPi1321 piModbusMaster [539]: modbus rtu minimal time between telegrams: 0 s 15625 us. Next problem can be on RTU wire line so you need differ these 2 situations. Mar 16, 2019 · the binding does not support Modbus RTU over Modbus TCP. 1. To do this, go to File→Save Workspace. Enter the devices IP address, leave other setting at their default. Nov 2, 2017 · Nov 2, 2017. Dec 6, 2014 · I got mbslave_pde_example sketch (txt file attached) from internet, and test it by these parameters: baud rate: 115200 8 data bits even parity 1 stop bit response timeout: 2000 ms delay between polls: 20 ms but mo&hellip; May 19, 2023 · That COM port has to match the setting in Modbus Poll's connection setup. 11. An example program illustrates the issue and my attempted fixes: #include <modbus/modbus. What step might we have done wrong? Thank you! Like. I connect to loopback 127. 要解决Timeout Error问题,需要针对通讯超时和数据冲突的原因进行分析,并采取相应的优化措施来减少通讯延迟。. In any dialog box you can press the F1 key for more help on that specific topic. According to the help file, this setting makes the PLC become a little more relaxed on the strict inter character timeout. From what I've read, there no need to set much configuration on the Cisco 2960X. 2 which are failing to bootup with WD-Timeout error: Modbus timeout error: plc modbus rtu timeout oscillascope: GE MarkVIe (Migration) - IONet Timeout \ Watchdog Protection Trip Nov 24, 2022 · I have tried adding basic delays to the python code (time. "Result" returns '0x00' if the Modbus transaction was successful but when I run the code I only get "0xE2" which according to the ModbusMaster. 3 KB. That means you can open several windows showing different data areas or data from different slave ID's at the same time. The Modbus RTU spec is very rigid about that. J. AFTER you open the comm handle, use the “set. เริ่มจากเปิดโปรแกรม Modbus poll ขึ้นมาหน้าต่างของโปรแกรมจะแสดงดังรูป ท าการ Connect เซนเซอร์กับโปรแกรม Toolbar > Connection > Connect Sep 22, 2016 · The default is in fact 10 seconds for TCP comm handles. Hi there. com/t5/NI-Labs-Toolkits/LabVIEW-Modbus-API/ta-p/3524019 Nov 27, 2023 · Strange that both ModScan and Modbus Poll would show timeout errors or insufficient bytes under different scenarios when it's an incorrect CRC all the time. My flowmeters are RS-485, 38,400 baud, Modbus RTU. So you will need to setup a cycle in your code. On your starting register, you need to drop the leading 10000 or 30000 or 40000 - that is an old modicon way of addressing that isn’t used in the current May 24, 2021 · EDIT 2: I have tried to incorporate minimal modbus structure but to no avail. 115 with subnet 255. Sep 25, 2018 · The result is 125ms. Jul 22, 2022 · Rating: (532) Modbus slave devices can fail to reply to requests for many reasons: 1. Hey, I also checked the “debug_connection = true” and I received the following information. Tried restarting, etc. Don't experiment. For example, to set it to one second using OptoScript, it’d look something like: SendCommunicationHandleCommand (chTCPHandle, “set About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Jul 7, 2013 · 5. The first step to troubleshoot Modbus Ethernet timeout issues is to check the network configuration of your devices and cables. Apr 26, 2024 · However, the device should return a modbus error, not a timeout, so this may not be your only issue - but it is not unheard of for a modbus device to just not respond to invalid requests. 9 KB. The device address is 2. Aug 14, 2017 · There are a few ways to do this but you have to be very careful. modbus. Apr 2, 2024 · To do this, go to File→Save Workspace. May 20, 2024 · There are a collection of modbus nodes available for node-red which you will need to install. The timeout is 1000ms and the retries are 3 attempts. CRC checking on the serial messages: 1. The OS installed is Ubuntu 8. The server running KEPWare is at 192. Settings must be identical. sleep(2)) to slow down the Modbus requests but this had no impact on the errors. Increasing poll or activating fragmented still doesn't work. For each window you simply specify the Modbus slave ID, function The examples below use the FreeModbus library port for serial TCP slave and master implementations accordingly. Option 1: Use modbus broadcast (slave ID 0) to tell all slaves to accept data. modbus: (RTU client) Sent Serial PDU: 0x0300000001. 11 I get this output: qt. I have tried with function 3 (holding register) and function 4 (input register), using length 2 and address 0001. Modbus TCP device <---> Cisco 2960 Sau khi chọn kiểu kết nối Modbus TCP-IP xong chúng ta cần chọn Slave sao cho đúng với địa chỉ slave của Z-8AI. 1 KB. modbus poll一直是timeout error,Tx=3:Err=3可能你的串口驱动没有安装好,或者你的rs485线没有连接好,报timeout error是scan超时,你的扫描周期是1000ms,这个已经可以了,或者是你在台式电脑上面的COM口不是这个. ) 2. The Address and quantity can be found in the Modbus Remote IO manual for your particular device. There are 11 nodes in the package and they are grouped together in the Modbus section. May 4, 2023 · The problem. Your code controls the polling interval. 1) You are doomed to failure if you experiment with the serial settings (baud rate, parity). W Jan 16, 2024 · Created by: edurov at: 1/16/2024 1:53 PM (1 Replies) Sep 19, 2022 · Hi all, I'm having some odd issues when trying to read Modbus TCP registries from a Modbus device to a Schneider PLC via a Cisco 2960X. Timeout: 2000 ms ( I tried also 10000ms ) PS. ni. Non galvanic isolated rs485 connector, works fine for million+ polls. Modbus-TCP is the most common TCP/IP version of the protocol. I checked the connection with Modbus Poll with same settings and it worked fine. 3 in help). 0 Kudos. Converters that work for Modbus TCP?RS-485 are specifically designed for such and sold for Modbus service. Understand the causes and effective troubleshooting techniques for a Apr 17, 2014 · is to test the softwareSerial port, not related with modbus and I already remove it. Feb 17, 2024 · The following pictures showing the results: Galvanic isolated rs485 connector with A and GND connected, works fine for million+ polls. My service (coded in Python using twisted for TCP) receives the request, properly Jul 27, 2021 · The holding register polling works multiple times until it stops with a timeout where only a (manual/auto) restart of the adapter solves the issue. my CP is Server, it's provide some data. 4 seconds = occasional errors. The interval is the duration between successive rising edges of the REQ input to the Modbus_Master block. This picture shows two open windows one reading 0A: The Slave Address ( 0A hex = address10 ) 81: The Function Code 1 (read Coil Status - with the highest bit set) 02: The Exception Code. We have the same IP address assigned to the Config and Modbus TCP server interfaces Summary: Learn how to identify and address ModBus timeout errors in electronic systems. But ModScan uses 1-based register numbering, so when you enter 261 for the address, it actually equates to 40261. This is my test code: QModbusTcpClient *modbus = new QModbusTcpClient (this); connect (modbus, &QModbusClient::timeoutChanged . Configure the settings to match on both ends. Jan 20, 2021 · Your TX and RX packets are identical. #2. That is correct. qt. Jan 4, 2022 · debug_connection = true. While debugging with Wireshark I see it queries just fine but because it’s too slow (scan_interval is set to 1) the Jan 4, 2021 · peacefair DC-017 Temco modbus poll L635 KO 799×412 45. if still any query let me know in the comment box----- Mar 13, 2019 · This code should poll the value of holding registrar 48 on the analog output module and print the "Result" back into the serial port 0. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Dec 25, 2015 · I have verified the functionality of converter and modbus hardware using modbus simulator (Pollscan, modbus poll) I believe i am making some mistakes in setting up the properties of tcpclient, but not sure what exactly. 5 char (t3. 8bit数据. Following the Function Code is the Exception Code. 按钮. May 31, 2018 · NI has a newer Modbus library that I'd recommend you try instead of the old one you're using. Oct 27, 2016 · Logic Machine Forum › LogicMachine eco-system › Scripting Modbus TCP/IP timeout error Oct 14, 2022 · I'm using a number of Modbus RTU devices connected to my PC through a Modbus TCP gateway. Jun 25, 2018 · Hello, Our program has been running on a cRIO for a while, reading data using Modbus RTU (Modbus VIs from DSC Module / Real-Time Module). But I experience a different behavior. Every slave has a uniqure address, and will only respond to requests that are addressed to it. Oct 18, 2023 · Modbus TCP-Slave Null Exception,Object reference not set to an instance of an object 1 How to recognize protocol and port settings in communication with Modbus boiler Apr 1, 2017 · On some systems, CTS has pull-up resistors to hold the input aserted and therefore the equipment will transmit regardless if anything is connected to CTS. It appears that your RS-485 adapter may be receiving its own transmissions. Modbus Poll is a Modbus master simulator designed primarily to help developers of Modbus slave devices or others that want to test and simulate the Modbus protocol. Instrument('COM6',ADRH1) # open serial port H2. I intend to clean it once I get it working correctly. KEPWare Config: KEPWare is configured with the Oct 14, 2016 · Baud rate: 38400. COM 串口选择(根据usb接口不同,每次显示的也不同). 1) Disable flow control on the RS232 side. Modbus: The operation is not allowed on non-connected sockets. Set a default of say 10 minutes (600 seconds), but allow users to disable it or set it to another time. Mar 2, 2019 · The Modbus TCP slave: OpenHABmodbus1983×220 11. B053: The CRC (cyclic redundancy check). I recommend submitting these traffic capture images to the manufacturer. It is difficult to verify as the origin Apr 17, 2017 · Modbus RS-485 Checksum and insufficient bytes received errors: Checksum error, Insufficient bytes recieved, Timeout - Modbus Poll: Insufficient bytes recieved: Modbus poll error- time out/checksum error/ insufficient bytes received: Bytes Missing Error Apr 17, 2021 · #modbus#modscan#modbuspolluseThis video for don't know how to use Modbus poll . 5) silent interval between two frames. The laptop has an rs485 to usb converter like on the picture. 3 MODBUS DEBUGGING TOOLS. The Modbus device is at IP 192. 通过网络优化和通讯设置调整,可以有效降低Modbus Poll中Timeout Error的发生率 Sep 28, 2018 · At least, I would expect a "timeout" exception when I try to read/write something. I'm getting a timeout on all read calls. T3-8I13O Temco modbus poll L635 KO 793×590 54. Cài đặt địa chỉ Slave cho modbus Poll. I am using Modscan64 to poll a service using TCP. The possible codes are shown in the table below. The exception code gives an indication of the nature of the problem. 28 in help). Dec 22, 2019 · 1. Export names and values to a Comma, Semicolon or Tab Separated Values File. May 4, 2018 · Thanks, David, I'm pretty sure I'm addressing slave 1, but I'm not certain the command itself isn't the issue, which could result in the same. dv ip dj jg kq tq ki mo kl as